Loading...

FAQ

What thickness of levelling compound is required on top of the underfloor heating??

sellUnderfloor heatingsellInstallation and technologysellPlanning

The actual required layer thickness of the levelling compound depends on the chosen kit and the desired top covering. With dry-lay systems, it is sufficient to fill the milled grooves with construction chemicals. Systems using studded panels or clip-on rails require a minimum cover depth of 3 mm over the heating pipes. However, this minimum cover depth is only recommended when using tiles and ceramic floor coverings. Other floor coverings require an additional 5 mm of cover depth.

The levelling compound used should always be flexible and bear the manufacturer’s specification stating that it is suitable for low-layer underfloor heating. To ensure the best possible heat transfer, the levelling compound should be applied as thinly as possible. Information on the thermal resistance of standard floor coverings can be found in the technical data sheet for underfloor heating.

Data sheet underfloor heating

enableFAQ list

play_circleback-to-top