How much weight does the thin-layer underfloor heating put on the floor?

sellUnderfloor heatingsellInstallation and technologysellPlanning

For structural calculations in the run-up to a house modernisation, it is sometimes necessary to know how much weight the underfloor heating will put on a floor. Of course, the weight depends on the individual floor structure and the materials used. Nevertheless, the weight of the FLEXIRO components can be calculated.

The levelling compound accounts for the majority of the total weight. The specific weight of a levelling compound is typically between 1.6 and 1.8 kg/m² per 1 mm layer thickness. With a construction height of 17 mm, an estimated weight of approx. 26 kg/m² can be expected. The underfloor heating itself adds only approx. 1.9–2.2 kg/m², even when filled with water. Therefore, the thin-layer system is much lighter than a standard underfloor heating system where the heating screed must be included in the calculation.